Showing posts with label EMC. Show all posts
Showing posts with label EMC. Show all posts

Tuesday, June 18, 2013

Cisco MDS port zoning 101

Objective

  • There are two FC ports (fd0, fd1) on a hp-ux rp3410 (hostname: rp3410 :) )
  • The storage is EMC VNX5100, we will use SPA P1/P2 and SPB P1/P2.

Physical connection

  • rp3410 fd0 will connect to SW1 port 1/7
  • rp3410 fd1 will connect to SW2 port 1/7
  • VNX5100 SPA P1 on SW1 port 1/1
  • VNX5100 SPB P1 on SW1 port 1/2
  • VNX5100 SPA P2 on SW2 port 1/1
  • VNX5100 SPB P2 on SW2 port 1/2

Switch configuration:

We will create 4 zones, 2 on each switch: The zoneset is "full-zoneset"

SW1 wwn is 20:00:xx:xx:xx:xx:xx:xx
SW2 wwn is 20:00:yy:yy:yy:yy:yy:yy

The VSAN of SW1 is 201, SW2 is 202

(it is port zoning, for soft zoning by wwn, it will be ready later)

SW1:
config t

vsan database
vsan 201 interface 1/7
 
interface 1/7
no shutdown
switchport mode F
switchport description "rp3410_fd0"

zone name rp3410_fd0_VNX5100_VNX_SPA1 vsan 201
member interface fc 1/1 swwn 20:00:xx:xx:xx:xx:xx:xx
member interface fc 1/7 swwn 20:00:xx:xx:xx:xx:xx:xx

zone name rp3410_fd0_VNX5100_VNX_SPB1 vsan 201
member interface fc 1/2 swwn 20:00:xx:xx:xx:xx:xx:xx
member interface fc 1/7 swwn 20:00:xx:xx:xx:xx:xx:xx

zoneset name full-zoneset vsan 201
memeber rp3410_fd0_VNX5100_VNX_SPA1
memeber rp3410_fd0_VNX5100_VNX_SPB1
zoneset activate name full-zoneset
 
SW2
config t

vsan database
vsan 202 interface 1/7

interface 1/7
no shutdown
switchport mode F
switchport description "rp3410_fd1"

zone name rp3410_fd1_VNX5100_VNX_SPA2 vsan 202
member interface fc 1/1 swwn 20:00:yy:yy:yy:yy:yy:yy
member interface fc 1/7 swwn 20:00:yy:yy:yy:yy:yy:yy

zone name rp3410_fd1_VNX5100_VNX_SPB2 vsan 202
member interface fc 1/2 swwn 20:00:yy:yy:yy:yy:yy:yy
member interface fc 1/7 swwn 20:00:yy:yy:yy:yy:yy:yy

zoneset name full-zoneset vsan 202
memeber rp3410_fd1_VNX5100_VNX_SPA2 vsan 202
memeber rp3410_fd1_VNX5100_VNX_SPB2 vsan 202
zoneset activate name full-zoneset

Monday, October 08, 2012

Symmetrix Command Line

My current job needs to take care of some EMC storages, from DMX to VMAX (also some Clariion/VNX and Celerra). Since I forget all the symcli commands, I created the following tables for quick reference (the table will be updated time to time...) :

symcfg list -sid -v

symcfg list -sid -applications

symcfg list -sid -connections
symcfg list -sid -connections -sorthost        
symcfg list -sid -connections -capacity

symcfg -dir all list -sid
symcfg -dir all list -sid -address
symcfg -dir all list -sid -address -available

 symcfg -sa all list -sid
 symcfg -da all list -sid
SA: fc address
DA: disk address
symcfg -fa all list -sid
symcfg -fa all list -sid -port
check wwn and fibre connection
 symcfg -sid  list -memory
Memory board
symcfg list -upatches -sid 
Patches
symcfg -sid  list -env_data
 symcfg show -sid  SystemBay -env_data
Hardware check
symcfg list -pools -sid
 symcfg list -pools -sid -gb

symcfg list -pools -sid 3281 -gb -detail -thin
Thin pool only
 symcfg list -datadev -sid 1226
 symcfg list -datadev -sid 1226 -range 0000:0001
 symcfg list -datadev -sid 1226 -range 0000:0001 -dev
 symcfg show -pool <> -thin -gb -detail


Thin pool only
 symcfg -sid $SID list -rdfg all
 symcfg -sid $SID list -rdfg all -rdfa





   
 symconfigure -sid $SID list -freespace

 symdev list -sid $SID -da all -space
symdev list -FA 7E -sid $SID (can use symcfg list -dir ALL to check)
 symdisk list -sid $SID -da <> (can use sycmfg list -da all to check)

sympd list -sid $SID
 sympd list -sid $SID -v

symdev list -inventory

 symdisk  -sid $SID show 7A:C4
 symdisk list -sid $SID -da
symdisk list -sid $SID -by_diskgroup